Page view 41
Complaint Problem Cause
Solution
Water is running to
drain continuously.
A. Control valve is
stuck in regeneration
cycle.
1. Electrical service to control(s) has
been interrupted.
1. Assure continuous electrical service is
available. (check plug, breaker, fuse, etc.)
2. Faulty circuit board.
2. Replace circuit board..
3. Faulty drive motor.
3. Replace drive motor.
4. Foreign material lodged in piston.
4. Disassemble and clean control valve,
replace seals, spacers and piston
assemblies.
Blue green staining. A. Corrosive water
condition in copper
distribution piping
system.
1. Low pH condition of the raw water
supply.
1. A Cullneu® filter may be required to
elevate the pH - consult factory.
2. In rare occasions, highly aerated
water in combination with a specific
water supply can create a slightly
corrosive condition.
2. Install a polyphosphate cartridge filter
after the Iron-Cleer Filter System to protect
the distribution piping.
Compressor doesn’t
run.
1. Compressor unplugged.
1. Plug it in.
2. Relay settings incorrect.
2. Set relay correctly.
3. Bad relay.
3. Replace relay.
Compressor run with
excessive noise.
1. Dead head pressure is 65 psi.
1. Consult factory.
2. Dead head pressure is 65 psi.
2. Rebuild compressor.
Compressor runs
continuously.
1. Incorrect relay settings
1. Set relay settings correctly.
2. Bad relay.
2. Replace relay.