Regeneration Interval - This setting is used to set the days between regeneration in time
clock mode. It is also active in meter or Aqua-Sensor
®
mode if the time clock backup DIP
switch # 10 is set to on. The display will show “REGEN” icon and “dAYS” as well as the
numbers to change. Adjust the value with the “Up” or “Down” keys.
Pressing the “Program” key will save the setting and move to the next programming step.
Day(s) of Week Regeneration -
In the time clock
mode only, the following optional days of the week
setting will be available to trigger regeneration.
The display will show “dAYoWK” for 2 seconds
followed by “NO”. The “Up” or “Down” key
will toggle “yes” or “no” (default is NO). A “yes”
response will indicate that the control is to perform
a regeneration on specific days of the week.
Pressing “Program” will save and advance to the next step. If “NO” was chosen, then the
control will only initiate regenerations based upon the interval (in number of days) and the
display will show as shown in Regeneration Interval above.
If “YES” was chosen, then the specific days of the
week to regenerate will be selected as follows:
The display will show “dAY” for two seconds
followed by “SUN N”. The “regen” key toggles the
days of the week and the “Up” and “Down” keys
toggle “Y or N”.
Pressing the “Program” key saves and advances
to the next step.
If any of the days were set to “yes”, the display will
show “SETDAY” followed by “SUN”. This selects
the current day of the week. The “Up” or “Down”
key toggles through the days of the week and
pressing the “Program” key saves the setting and
advances to the next programming step.
If ALL of the days were set to “no”, then specific day of week regens will be canceled and
in Regeneration Interval will appear, and the interval will be set in number of days.
Pressing the “Program” key saves the setting and advances to the next programming
step.
Filter Media Life This setting is used in Filter Mode ONLY with flow meter attached. It
enables or disables an alarm code (“Change Media”) that indicates the end of life for the
filter media. The display will show “Life” in the left most characters and toggle between
“Y” and “N” in the right most character with the “Up” and “Down” keys. If “No” is selected,
the alarm is disabled and the ‘Total Capacity’ setting will be treated as it is in Flow Meter
Mode (softener). If “Yes” is selected, the alarm is enabled and will sound when the ‘Total
Flow/Life of Unit’ statistic = ‘Total Capacity’ setpoint, indicating that it is time to change
the filter media.
Pressing the “Program” key will save the setting and move to the next programming step.
Note:
1. If any day of the week is set to “yes”, the regeneration interval in number of days (“Days 03”) will no longer appear when
going through the programming menu at a later time. To go back from specific day of week regeneration to interval in
number of days, choose “NO” at “dAYoWK”.
2. If a DIPswitch is changed anytime (other than run/test dip#1) after the control has been programmed to regenerate on
any specific day, all settings will revert back to default (“dAYoWK” = NO); specific days to regenerate and current day
will have to be reprogrammed.
Programming 21
NO
SUN
SUN N