IN-PLANT PREPARATION / 7
In-Plant Preparation
To help assure quick and trouble-free installation of the
Aqua-Cleer
®
system, the following preparation steps should
be performed in the dealer facility. Refer to Fig. 2. Cleanliness
is essential in the In-Plant Preparation procedure. Be sure to
wash your hands throughly before handling filters.
The use of surgical gloves is strongly recommended.
Filter Assembly Preparation
• Activated Carbon Filter
The activated carbon filter must be thoroughly flushed
to remove carbon dust which can plug the manifold or
RO membrane filter. To perform this procedure, it is
necessary to use a clean, spare Aqua-Cleer H-83 (or
H-82, 52, 53) series or “System” series filter housing
(Fig. 4) as a service housing.
1. Install the activated carbon cartridge into the service
housing.
FIG. 4
2. Connect the outlet of the service housing to a source
of clean, filtered water.
3. Connect the inlet of the service housing to a suitable
drain.
4. Slowly turn on the water and back-flush the filter for
5 minutes at a rate of 1-2 gpm (4-7 L/min). Turn the
water on and off several times during flushing to help
loosen carbon particles from the filter.
5. Reverse the connections and forward flush the filter
briefly until the water runs clear.
6. Remove the activated carbon filter cartridge from the
service housing and set it aside in a clean location for
installation into the Aqua-Cleer system.
• Sanitize Filter Assembly
The Aqua-Cleer system may be sanitized with either
5-1/4% liquid chlorine bleach or a fresh bottle of
consumer grade hydrogen peroxide.
NOTICE: Chlorine will damage the RO membrane
filter in this system. Remove the RO membrane filter when
using chlorine bleach to sanitize.
NOTICE: Do not use hydrogen peroxide if iron is present
in the raw water supply. This combination will damage
the RO membrane filter.
1. Pull the u-clip from the rear of the particle filter
housing
2. Insert the u-clip into the two square holes at the
bottom rear of the manifold. Push up to release the
filter housing.