Culligan GoodWater Machine DrinkingWater System Specifications Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
4 / AQUA-CLEER
®
/GOOD WATER MACHINE
DRINKING WATER SYSTEMS
Product Information
This manual covers the technical aspects of the Culligan
®
Aqua-Cleer
®
Good Water Machine
AC model drinking wa-
ter systems. It is important to read this manual thoroughly so
that you can properly apply, install, and service these
systems.
The substances removed by this system are not necessarily
in your untreated water. See Performance Data Sheet for
exact percentages of contaminant removal.
Packaging
The Aqua-Cleer system is shipped from the factory in two
cartons:
Carton 1: Carton 2:
• Filtration Assembly • Storage Tank
• Reverse Osmosis Membrane
Filter Element
• Particle Filter Element
Activated Carbon Filter Element
• Polishing Filter w/Mounting Pad
• Parts Package, including:
• Faucet
• Tank Valve
• Mounting Bracket
• Product Literature
Note that the filter elements are shipped in their own sealed
packaging. This will help to simplify in-plant preparation of
the system and to maximize the shelf life of the RO
membrane filter element.
If the Aqua-Cleer system will not be installed immediately,
refrigerate the RO membrane filter element at 35°/40°F
(2°/5°C). DO NOT ALLOW TO FREEZE.
Warranty
A limited warranty is extended to the original end user from
Culligan. This warranty is printed on the back cover of the
Owners Guide.
Application Guidelines
The Aqua-Cleer/Good Water Machine system is designed for
use on potable water supplies meeting the guidelines out-
lined in Table 1. The system should be installed on your
home’s cold water line. The flushing stream should discharge
through an approved siphon break. Installation of this
system must comply with state and local laws and
regulations.
1
Nitrate units are not certified for nitrate reduction in
water supplies with a pressure less than 40 psi (280 kPa).
A booster pump is strongly recommended.
2
See the "Performance & Technical Information" section
of this manual for all applications where TDS
exceeds 1000 ppm (1000 mg/L). A booster pump is
strongly recommended.
3
The reverse osmosis membrane filter used in this system
may be damaged by chlorine. This system includes an
activated carbon filter which protects this element by
reducing chlorine. Influent chlorine should not exceed
3 mg/L.
High Efficiency Operation
The Aqua-Cleer system is designed for high-efficiency
operation. Soft water use is strongly recommended. For
maximum RO membrane filter life on all hard-water installa-
tions, adjust the capillary length as described in the
“In-Plant Preparation” section of this manual. (Not required
for LC-50)
Influent Water Characteristic
Pressure
1
40-120 psi (280-827 kPa)
Temperature 33-100°F (1-38°C)
Total Dissolved
Solids (TDS)
2
0-4000 ppm (0-4000 mg/L)
pH 5-10
Chlorine
3
0-3 ppm (0-3 mg/L)
Chloramine 0-3 ppm (0-3 mg/L)
Turbidity 0-10 NTU
Iron 0-1 ppm (0-1 mg/L)
Bacterial Quality Potable
TABLE 1