Water Softener
Programming
Pre-Rinse Mode - This setting will only be active if dip#9 is on. The display will show "PRE-" for two seconds and then
"RINSE" in the left most characters of the display. When "RINSE" is shown the right most character of the display will
flash "N" and toggle to "Y" with the use of the "+" or "-" keys.
Pressing the "Status" key will save the setting and move to the next programming step.
Pre-Rinse Time Duration - This setting is used to set the length of time that
the control will be in the fast rinse position before returning to the Service
(Home) position. The display will show "RINS" and XX where XX is the length
in minutes that the control is to pre-rinse as well as the "FAST RINSE" icon.
Adjust the XX value with the "+" and "-" keys.
Pressing the "Status" key will save the setting and move to the next
programming step.
Pre-Rinse Hours - This setting will only be active if the Pre-Rinse mode is set
to 'Yes' and a flow meter is attached to the control. The display will show
"HOUR" in the left most characters and "XX" in the right most digits where "XX"
represents the hours setting from 01 - 99. The hours setting is adjusted with
the "+" and "-" keys.
Pressing the "Status" key will save the setting and move to the next
programming step.
Pre-Rinse Time of Day - This setting will only be active if the Pre-Rinse mode is set to 'Yes' and the control is operating
in time clock or Aqua-Sensor
®
mode. The Display will show "TIME" for 2 seconds and then the flashing time display as
in the time of regeneration display. The time can be adjusted in 30 minute increments with the "+" and "-" keys.
Pressing the "Status" key will save the setting and move to the next programming step.
Efficiency Mode (flow meter only) - Efficiency mode will only be active if the
conditions as explained earlier are met (Not available if DIP switch #6 or DIP
switch #9 are on). The "EFFICIENCY MODE" Icon will be displayed with a
default of "YES". Toggle between "YES" and "NO" with the "+" or "-" key.
Pressing the "Status" key will temporarily store the setting and move to the next
programming step. (This setting will not get saved to EEPROM until the 'status'