Culligan Platinum Series Specifications Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 71
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
Programming 25
Programming Menus
The programming menus will vary depending on which devices are connected to the circuit board and dip switch settings.
Pressing the "Status" key enters the standard programming mode. Repeated presses of the "Status" key will scroll through the program-
ming menu to each desired setting. The value is then set by using the "+" and "-" keys to increment or decrement the value. Pressing the
"Status" key, after value selection, saves the programmed value to EEPROM (unless otherwise specified; some settings are temporarily
stored before they are saved). To exit the programming mode, repeatedly press the "Status" key until the display returns to time of day dis-
play. The following table outlines all of the programming functions, range limits and default settings:
Setting Range Limits Default Comments
* Beeper Toggle (Y / N) Y E n a b l e / d i s abl e the key press beeper (ERR/Alarm Code beeps can't be disab l e d )
Time of Day
12:00AM-11:59PM(12hr)
00:00-23:59 (24hr)
12:00 PM 12:00 12 / 24 hour function set with dip#8
* Time of Regen
12:00AM-11:30PM(12hr)
00:00-23:30 (24hr)
2:00 AM 02:00 Adjustable in 30 minute increments only
* Regen Interval Days - 1 to 99 days 3 days Displayed in Time Clock Mode (displayed in Flow Meter and A/S If dip#10 on)
*‡ Hardness Type
S - Standard Metric,
F - French Metric,
D - German Metric
S - Standard Metric
Only active with flow meter if dips#3&4 are set to Gold or Platinum and dip#7 is set to 'metric'
(Not available in Filter operation)
*‡ Hardness
1 - 110 English
1 - 110 Standard Metric
2 - 189 Metric French
1 - 105 Metric German
25 - English
25 - Standard Metric
43 - Metric French
24 - Metric German
Only displayed if DIP Switch 3 & 4 are set to Gold or Platinum and flow meter attached (Not
available in Filter operation)
*‡ Iron 0 - 5 0
Only displayed if DIP Switch 3 & 4 are set to Gold or Platinum and flow meter attached (Not
available in Filter operation)
*‡ Salt Type KCl or NaCl NaCl
Only displayed if DIP Switch 3 & 4 are set to Gold or Platinum and flow meter attached (Not
available in Filter operation)
*Predict Mode Yes or No No
Only Active if DIP Switch 9 is on and DIP Switch 6 is off and a flow meter is connected to the
control (Not available in Filter operation)
*Pre-Rinse Mode Yes or No No Only active if DIP Switch 9 is on.
*Pre-Rinse Duration 01 - 15 05 Only active if DIP Switch 9 is on and the Pre-Rinse mode is set to 'Yes'.
*Pre-Rinse Hours 1 - 240 24
Only active if Dip Switch 9 is on and Pre-rinse mode set to yes and a flow meter is connected to
the control
*Pre-Rinse Time of Day
12:00AM-11:30PM(12hr)
00:00-23:30 (24hr)
5:00 AM 05:00
Only active if Dip Switch 9 is on and Pre-rinse set to 'yes'; Adjustable in 30 minute increments
only; Available only in TimeClock and Aqua-Sensor
®
mode (not meter mode)
*‡ Efficiency Mode Yes or No No
Available only if DIP Switch 3 & 4 are set to Gold or Platinum with flow meter connected; Iron =
0; Hardness <= 20 (English hardness units) "Efficiency Mode" icon lit when enabled (Not avail-
able if dips#6or9 on, or Filter mode)
*‡ Gold Tank Size 9x48, 10x54, 12x52, 14x65 9x48
Only displayed if DIP Switch 3&4 are set to Gold or Platinum, respectively and a flow meter is
connected (Not available in Filter operation)
*‡ Platinum Tank Size 10x54, 12x52, 14x65, 16x65 10x54
*‡ Defaults Yes or No Yes
Only displayed if DIP Switch 3&4 are set to Gold or Platinum and a flow meter is connected.
(Not available in Filter operation)
View Y or N N Only displayed if "Defaults" was set to "YES"
*Salt Dosage 3 - 60 Lbs 0.5 - 27.5 kg
Timeclock/ Aqua-Sensor
®
:
7Lb/3.0kg; Flowmeter: default
varies based on tank size
If DIP Switch 3 & 4 are set to Gold or Platinum (Not Available if DIP Switch 3 & 4 are set to
other.) (Not available in Filter operation)
* Meter "K" Factor 0.5 - 500 50.0 Only displayed with Flow meter connected and DIP Switches 3 & 4 on (other).
* Cycle 1 time 1 to 99 minutes 10min (5min efficiency mode)
* Cycle 2 time 1 to 99 minutes
Softener mode-TC mode or
dips#3&4 set to other-60 mins;
Flow meter-lookup table; A/S
mode-99 minutes Filter mode -
2 minutes
-Softener / Filter function set with DIP switch #2
-For Gold or Platinum: cycle time default is loaded from table;
-flow meter must be connected
* Cycle 3 time 1 to 99 minutes 10 minutes Only displayed if DIP Switch 3 & 4 are set to Platinum or Other.
* Cycle 4 time (if 5 cycle valve) 1 to 99 minutes 10 minutes Filter-2 minutes Only displayed if DIP Switch 3 & 4 are set to Platinum or Other(with 5 cycle valve detected)
*** Day(s) of Week Regen 'dAYoWK' Yes or No No Time Clock Mode Only; Active for softener and filter
***Regeneration Day(s)
Scroll days of the week,
Toggle Y/N
SUN N Only active if 'dAYoWK' was set to 'Yes'
*** Current day of week Scroll days of the week SUN Only active if at least one day of the week was 'Y' in 'Regen Day(s)' above
* Total Capacity Set Point
(MaxCap)
1 - 999,999 (can't be set less
than BATCH)
999,999 (other or filter);
Calculated for (Gold or Platinum
softeners)
-Set point to trigger immediate regen -Only active with flow meter connected -(For Filter opera-
tion, see filter media life feature description)
*Filter Media Life Toggle (Y or N) N Enable/disable the filter media life feature (filter Operation ONLY)
* Batch Capacity
1 - 999,999 (can't be set
greater than MaxCap)
870 (other or Filter); Calculated
for (Gold or Platinum softeners)
-Only active with flow meter connected -For Gold or Platinum, the value shown is calculated by
control; value may be overridden by user by setting 'defaults' to 'no'
* Lock / Unlock Toggle Lock & Unlock Unlock
-Lock or unlock access to program changes -Only accessible from service mode, time of day
display; press and hold '+' and '-' keys together for 5 seconds- (not while in programming menu)
*To be saved in EEPROM
‡Temporarily stored value; only saved to EEPROM when 'status' key is pressed at 'dEFLtS' setting. This applies ONLY to flow meter mode, with dips#3&4 set to
Gold, Platinum, or Europe.
*** only active in time clock mode; value saved in EEPROM.
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 70 71

Comments to this Manuals

No comments