1
Performance
Specifications
Control Valve
10” Model
1 1/4” 5-cycle
Reinforced
Thermoplastic
12” Model
1 1/4” 5-cycle
Reinforced
Thermoplastic
14” Model
1 1/4” 5-cycle
Reinforced
Thermoplastic
16” Model
1 1/4” 5-cycle
Reinforced
Thermoplastic
Overall Conditioner Height 62 in 60 in 73 in 73 in
Media Tank Design Quadra-Hull
®
Quadra-Hull
®
Quadra-Hull
®
Quadra-Hull
®
Media Tank Dimensions
(Dia x Ht)
10 x 54 in 12 x 52 in 14 x 65 in 16 x 65 in
Salt Storage Tank
Dimensions (Dia x Ht)
18 x 43 in 18 x 43 in 24 x 40 in 24 x 40 in
Exchange Media, Type and
Quantity
Cullex
®
Media, 1.5 ft
3
Cullex
®
Media, 2.0 ft
3
Cullex
®
Media, 3.0 ft
3
Cullex
®
Media, 4.0 ft
3
Underbedding, Type and
Quantity
Cullsan
®
Underbedding,
15 lb
Cullsan
®
Underbedding,
20 lb
Cullsan
®
Underbedding,
25 lb
Cullsan
®
Underbedding,
30 lb
Exchange Capacity @ Salt
Dosage Per Recharge
28,210 gr @ 6.0 lb
38,260 gr @ 12.0 lb
45,338 gr @ 18.0 lb
31,952 gr @ 7.0 lb
53,438 gr @ 16.0 lb
62,941 gr @ 24.0 lb
56,420 gr @ 12.0 lb
76,520 gr @ 24.0 lb
90,676 gr @ 36.0 lb
63,904 gr @ 14.0 lb
106,876 gr @ 32.0 lb
125,885 gr @ 48.0 lb
Efficiency rated dosage
1
4,702 gr/lb @
6 lb salt dosage
4,565 gr/lb @
7 lb salt dosage
4,702 gr/lb @
12 lb salt dosage
4,565 gr/lb @
14 lb salt dosage
Freeboard to Media
2
14.5 in 16 in 25 in 25 in
Freeboard to
Underbedding
3
47.5 in 46 in 59 in 59 in
Salt Storage Capacity 375 lb 375 lb 600 lb 600 lb
Rated Service Flow @
Pressure Drop
14.9 gpm @ 15 psi 19.5 gpm @ 15 psi 20.5 gpm @ 15 psi 22.9 gpm @ 15 psi
Total Hardness, Maximum 99 gpg 99 gpg 99 gpg 99 gpg
Total Iron, Maximum 5 ppm 5 ppm 5 ppm 5 ppm
Hardness to Iron Ratio,
Minimum
8 gpg to 1 ppm 8 gpg to 1 ppm 8 gpg to 1 ppm 8 gpg to 1 ppm
Operating Pressure 20-125 psi 20-125 psi 20-125 psi 20-125 psi
Operating Pressure
(Canada)
20-90 psi 20-90 psi 20-90 psi 20-90 psi
Operating Temperature 33-120°F 33-120°F 33-120°F 33-120°F
Electrical Requirements 24V/60 Hz 24V/60 Hz 24V/60 Hz 24V/60 Hz
Electrical Power
Consumption, Min/Max
3 Watts/35 Watts 3 Watts/35 Watts 3 Watts/35 Watts 3 Watts/35 Watts
Drain Flow, Maximum4 2.0 gpm 3.5 gpm 5.0 gpm 6.0 gpm
Recharge Time, Average
5
85 min 84 min 82 min 96 min
Recharge Water
Consumption, Average
5
54 gal 80 gal 181 gal 183 gal
1 The efficiency rated dosage is only valid at the stated salt dosage and maximum service flow
rate and is efficiency rated according to NSF/ANSI 44.
2 Measured from top of media to top surface of tank threads. (backwashed and drained).
3 Measured from top of underbedding to top surface of tank threads.
4 Backwash at 120 psi (830 kPa).
5 10 minute backwash, 6 lb 10” model, 7 lb. 12” model, 12 lb. 14” model or 14 lb. 16”