Culligan Platinum Series Specifications

Browse online or download Specifications for Water dispensers Culligan Platinum Series. Culligan Platinum Series Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1

Culligan® Platinum Plus SeriesAutomatic Water Conditioner Owners Guide

Page 2 - With Culligan Water

6The Culligan ProcessYour Culligan water conditioner consists of three basic components, (A) the Control Valve, (B) the Mineral Tank, and (C) the Brin

Page 3 - Contents

7Modes of OperationWater Meter ModeIn water meter mode, the controller keeps track of the quantity of water that has flowed through the resin bed. Base

Page 4

8PreparationComponent DescriptionThe water conditioner is shipped from the factory in a minimum of three cartons. Remove all components from their car

Page 5 - Specifications

9Preparation (cont.)ApplicationWater quality - Verify that raw water hardness and iron are within limits. Note the hardness for setting the salt dosag

Page 6 - Introduction

10InstallationWith the exception of media containers, open the remaining containers, remove all the components, and inspect them before starting insta

Page 7

11Installation (cont.)Loading the Tank (12”, 14” and 16” Tanks)1. Position the tank so that the Culligan® logo is in the front. 2. Remove the inlet

Page 8

12Installation (cont.)Mount the Control ValveSee Figure 4 for a visual on mounting the control valve to the tank.• Remove and discard the protective

Page 9 - How Your Water

13Installation (cont.)Flow Control Eductor NozzleListed below is the recommended eductor nozzle to be used at various salt dosages.Tank Injector Dra

Page 10 - The Culligan

14Installation (cont.)Backwash Flow Control Replacement:• Remove the drain clip and pull the drain elbow straight off.• Remove the backwash flow cont

Page 11 - Operation

15Installation (cont.)Drain Line ConnectionRefer to Table 3, for drain line length and height limitations.• Remove 1/2” pipe clamp from the small par

Page 12 - Preparation

iThank YouAnd Welcome To Your New World Of Better Living With Culligan Water.The Culligan Platinum Plus Series Water Softeners with Soft-Minder® Mete

Page 13

16Installation (cont.)Brine Valve “A” DimensionThe Culligan Platinum Plus Series™ unit contains a brine float which can serve as a backup refill shutoff

Page 14 - Installation

17Installation (cont.)Connect the Brine Line• Measure a length of brine line sufficient to reach from the brine tank to the brine fitting, with no shar

Page 15

18ProgrammingPower LossThe AccuSoft® circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The capacitor is capable of maintaining

Page 16

19Programming (cont.)The Culligan® AccuSoft® Plus circuit board controls all the softener functions. These settings are programmed at the time of in

Page 17

20Programming (cont.)• Regeneration Interval - This setting is used to set the days between regeneration in time clock mode. It is also active in me

Page 18

• Efficiency Mode (flow meter only) - Efficiency mode will only be active if the conditions as explained earlier are met (Not available if DIP switch #6

Page 19

22Programming (cont.)• Salt Dosage - This setting is used to set the salt dosage. The display will first show “dOSAGE” for two seconds and then displ

Page 20

23Programming (cont.)• Total Capacity Set Point (Max Capacity) - This setting is used to program a value that corresponds to the maximum capacity tha

Page 21

24Statistic FunctionsThe statistical functions are reached by pressing the “Information” key. Repetitive presses of the “Statistics” key will cycle t

Page 22 - Programming

25Final Start-UpRegenerationThere are several conditions that will cause the control to trip a regeneration. The “REGEN” enunciator will light when t

Page 23

iiTable of ContentsPerformance Data Sheets are included in this manual for various Culligan Platinum Plus Series Softener models. Refer to the Perfor

Page 24

26Final Start-Up (cont.)Note: Unplugging the Culligan Platinum Plus Series water softener will not affect any of the control settings (The control m

Page 25

27Final Start-Up (cont.)Recommended Aqua-Sensor® Start-Up Procedure• Close the main water supply valve.• Install the sensor probe into the tank but

Page 26 - KG 3.O

28Salt Supply, Usage and ServiceSalt is the mineral used to “recharge” your water conditioner. A brine solution is automatically made up in the bottom

Page 27 - OOO8 7O

29Care and Cleaning of your Water ConditionerFollowing these simple precautions will help assure continued trouble-free service and keep your Culligan

Page 28 - Functions

30Care and Cleaning of your Water Conditioner (cont.)To Clean Out the Salt Storage TankA periodic clean-out of the Salt Storage Tank is necessary to k

Page 29 - Final Start-Up

31Care and Cleaning of your Water Conditioner (cont.)Sanitizing ProcedureA water softener in daily use on a potable water supply generally requires no

Page 30

32Things to Check Before Calling for ServiceIf you unexpectedly experience hard water, make these simple checks before calling your Culligan dealer.

Page 31

33Error CodesThe Accusoft Plus microprocessor is equipped with an advanced error detection system. During all operating modes the softener’s electroni

Page 32 - Usage and

34BypassWhen and How to Bypass Your Water ConditionerNormally, all water except outside lines passes through the water conditioner. There are times wh

Page 33 - Conditioner

35Performance Data SheetCulligan Platinum Plus Series 10” Water Softener with Soft-Minder® MeterCulligan knows the more informed you are about your wa

Page 35

36Performance Data SheetCulligan Platinum Plus Series 10” Water Softener with Aqua-Sensor® Sensing DeviceCulligan knows the more informed you are abou

Page 36 - Before Calling

37Performance Data SheetCulligan Platinum Plus Series 12” Water Softener with Soft-Minder® MeterCulligan knows the more informed you are about your wa

Page 37 - Error Codes

38Performance Data SheetCulligan Platinum Plus Series 12” Water Softener with Aqua-Sensor® Sensing DeviceCulligan knows the more informed you are abou

Page 38 - Bypass Valve

39Performance Data SheetCulligan Platinum Plus Series 14” Water Softener with Soft-Minder® MeterCulligan knows the more informed you are about your wa

Page 39 - Data Sheet

40Performance Data SheetCulligan Platinum Plus Series 14” Water Softener with Aqua-Sensor® Sensing DeviceCulligan knows the more informed you are abou

Page 40

41Performance Data SheetCulligan Platinum Plus Series 16” Water Softener with Soft-Minder® MeterCulligan knows the more informed you are about your wa

Page 41

42Performance Data SheetCulligan Platinum Plus Series 16” Water Softener with Aqua-Sensor® Sensing DeviceCulligan knows the more informed you are abou

Page 42

43Table 4 - Maximum Allowable Drain Line LengthOperating Pressure0ft (0m) 2ft (0.6m) 4ft (1.2m) 6ft (1.8m) 8ft (2.4m) 10ft (3m)30psi (210 kPa)60 ft

Page 43

44Parts ListHead Assembly789101112131321817161514135134619201920

Page 44

45Parts ListHead AssemblyItem No. No.Req’d Part No. Description 1 1 - Backplate2,3,4 1 01019693Backplate Adapter Kit - Includes Backplate Adapter, 4

Page 45

1Performance SpecificationsControl Valve 10” Model 1 1/4” 5-cycle Reinforced Thermoplastic 12” Model 1 1/4” 5-cycle Reinforced Thermoplastic 14” Model

Page 46

46Parts ListValve Assembly

Page 47 - Appendix A

47Parts ListValve AssemblyItem No. No.Req’d Part No. Description 1 1 01018690 Control Valve, Assembled 2 1 01019662 Piston Assembly 3 3

Page 48 - Parts List

48Parts ListBypass Assembly155432Item No. No.Req’d Part No. Description 1 1 01019718 Bypass Valve Assembly2 2 01019697 Connector, 1” NPT w/ O-Ring

Page 49

49Parts ListTank AssemblyItem No. Part No. Description Qty. 01-0166-18 Tank Assembly, 10” w/ Fillport, Complete 01-0171-92 Tank Assembly, 12” w/

Page 50

50Parts List16” and 18” Brine SystemsItem Part No. Description - 01-0187-05 Brine System, 250 lb - 01-0187-15 Brine System, 375 lb 1 01-0187-09 R

Page 51

51Parts ListBrine ValveItem Part No. Description - 01-0187-06 Brine Valve 1 01-0187-10 BLFC Elbow - 0.45 gpm 01-0187-11 BLFC Elbow - 0.8 gpm 1

Page 52

52Parts List24” Brine SystemItem Part No. Description - 01-0187-20 Brine System, 650 lb 1 01-0187-18 Replacement Tank, 650 lb 2 01-0187-14 Cover

Page 53

53Circuit Board DiagramMotor and power wires are not polarity sensitivePower 24VPower 2.5VFlow Meter SensorMotorRear View of HH24 Circuit BoardRear Vi

Page 54

54Records and DataImportant Data on Your Water ConditionerIt is advisable to have the salesperson or installer fill in the information below for your

Page 55

55Culligan Limited WarrantyCulligan Platinum Plus Series Automatic Water ConditionersYou have just purchased one of the finest water conditioners made.

Page 56

2IntroductionRead this Manual FirstBefore you operate the Culligan Platinum Plus Series Water Softening System, read this manual to become familiar wi

Page 57 - Circuit Board

56With Culligan You Get More Than a Quality ProductYou Get Your Water Expert, The Culligan ManWe’re here to provide you with fast, dependable service,

Page 58 - Records and

3Introduction (cont.)It’s All So Easy, So Economical, So Efficient, So Enjoyable!Kind To Skin And ComplexionSoft water will help prevent red, itchy or

Page 59 - Warranty

4Introduction (cont.)Saves Water-Heating Energy, Helps Water-Using AppliancesSoft water reduces the formation of rock-like hard water scale which encr

Page 60 - Than a Quality

5How Your Water Conditioner WorksWhy Water Gets Hard And How It’s SoftenedAll of the fresh water in the world originally falls as rain, snow, or sleet

Comments to this Manuals