6
CAUTION: Damage or destruction to the media may occur if salts containing additives
are used with the Iron Soft Plus models. Most “solar” and/or “block” salts do not
contain additives detrimental to this unit. If unsure, please check with manufacturer.
Many “pellet” or “cube” type salts are formulated with cleaning agents or additives
which can cause harm to the media. Salt manufacturers do not always list additives in
their products. Please check with salt manufacturers for any cleaning agents, binders
or phosphate material added to salt.
NOTE: The manufacturer does recommend the brine tank be cleaned once a year to discard
accumulated dirt from the salt.
5. Press the button and place unit into the brine tank fill position. Check to verify that the
regenerant tank is filling at a rate of 1/2 gallon per minute. Check Brine line connections for leaks.
NOTE: See page 18, Safety Float Assembly, Item No. 2, for location of 1/2 gpm Refill Flow Control.
6. Press button again, valve will cycle back to the normal operating position with the time of day
and gallons remaining displayed.
7. Repeat steps 1-6 and now check the various cycles for proper operation.
8. Once the cycle operation has been verified, place bypass valve in the normal operating mode
(“Valves Open,” Fig. 3) by opening the outlet bypass handle.
9. Go to laundry tub or bathtub faucet, preferably a faucet without an aerator, and turn on the cold water,
let the water run. Note the color of water coming from faucet. If discolored let water run until clear.
NOTE: At no time should there be “large particles” of media noticed at faucet or laundry tub. If this
is seen, immediately shut off water and bypass system as this could be an indication of a distributor
failure. Contact manufacturer or distributor for assistance.
START-UP PROCEDURES FOR ELECTRONIC CONTROLLER CONTD:
TIMER DISPLAY DESCRIPTION
:
Page view 5