PRE-INSTALLATION INSTRUCTIONS:
Although the Iron Soft Plus Series Water Conditioner is shipped complete, some assembly may be required.
1. After unboxing the unit, please note that on most models the control valve is installed on the tank. If not,
remove “split flange” from control valve adapter base, remove cardboard tank shim. Inspect “O” Ring on
top of flange and grease with silicone provided. Place valve (shipped in a separate box) on adapter base.
The valve is “keyed” and will only attach one way. Using split flange, attach control valve to tank.
CAUTION: The “split flange” should secure the valve with the top of the flange
facing up. Please note “top” on the split flange.
2. Install the chlorine generator on the brine valve (Fig. 3) by inserting 3/8" tube and tightening the
nut. Plug generator’s electrical end into receiving adapter from the back plate. Do not install brine
line at this time.
CAUTION: Never grab onto the generator to move unit. This will result in
cracking the valve body.
3. Install meter and bypass, if ordered, (Fig. 3) using silicone grease provided on “O” Rings.
Extra “O” Rings have also been provided in case a tear occurs during installation.
NOTE: Meter should be installed between the control valve and the bypass with the meter
“turbine” being installed on the outlet side of the control valve (Fig.3).
4. Secure both the meter and the bypass using the clips provided.
NOTE: There will be some up and down “play” and should not be of concern since
the “O” Rings will seal and no leaks should occur.
INSTALLATION INSTRUCTIONS:
IMPORTANT: In the following installation instructions various types of plumbing pipe are recommended.
These types may or may not be approved for your local plumbing codes. All plumbing must be installed
according to local plumbing codes.
WELL WATER INSTALLATION
Figure 1
MUNICIPAL INSTALLATION
Figure 2
1. A selection site should be chosen for your conditioner. If you have a well system, this would be
after the pressure tank but before the hot water heater (Fig. 1). If you have city water, install the
softener on the inlet line to the building before the hot water heater (Fig. 2).
NOTE: Try to locate the softener as close to a drain (floor drain, sump pump, etc.) as possible.