Troubleshooting Guide
Water Volume and Quality
Symptom Condition Action
No product water Water supply is turned OFF Turn water ON
Not enough Low water pressure Check source water line pressure
product water
Inlet water supply valve is blocked Clear restriction
Storage tank valve is closed Open storage tank valve
Storage tank is depleted Increase product water storage
capacity and/or install membrane
with higher output rating
Clogged pre-filter cartridge(s) Replace pre-filter cartridge(s)
Storage tank air pressure charge Empty water from storage tank
is low (product water faucet must remain
open while adjusting pressure) and
adjust pressure to 55 kPa (8 psig)
System does not Shut-off valve is not closing Contact your Culligan
®
Dealer
shut off
No drain water Clogged flow control Replace flow control (Item 6) in
parts list and contact your
Culligan
®
Dealer
Water has Carbon post-filter is depleted Drain storage tank, sanitize system
offensive taste and replace carbon post-filter
and/or odor cartridge
Membrane depleted or fouled Smartap
®
Quality Monitor reads
yellow, or if TDS test is
unsatisfactory, drain storage tank,
sanitize system and replace
membrane
Sanitizer not flushed out Drain storage tank and let it refill
overnight