Culligan® Iron-Cleer® Plus Automatic Water Filter Owners Guide
Familiarization (cont.)Modes of OperationManual RegenerationPressing and holding the regen button for 3 seconds will initiate an immediate regeneratio
7The Culligan® AccuSoft® Plus circuit board controls all of the filter functions. These settings are programmed at the time of installation. The fol
8• Time of Regeneration - This setting is used to program the time at which a regeneration is to occur in the delay mode, or in immediate mode with t
9• Filter Media Life (Change Media) - This setting is used in Filter Mode ONLY with flow meter attached. It enables or disables an alarm code (“CHAN
10The statistical functions are reached by pressing the “Information” key. Repetitive presses of the “Information” key will cycle through the standard
11When and How to Bypass Your Water ConditionerNormally, all water except outside lines passes through the water conditioner. There are times when the
12Aeration Tank – Bypass Valve OperationNormal OperationBypass Operation“Treated” Water ExitsSupply Water EntersSupply Water ExitsSupply Water EntersS
13Things to Check Before You Call for ServiceIf you unexpectedly experience problem water, make these simple checks before calling your Culligan deale
Recommended Preventative MaintenanceThe Culligan Iron Cleer water filter has been designed to provide a good, consistent service life. Because of the
15Troubleshooting GuideComplaint Problem Cause SolutionIron bleed-through or staining.A. Inadequate backwash of filter1. Plugged drain line flow contr
Thank YouAnd Welcome To Your New World Of Better Living With Culligan Water.This system and its installation must comply with state and local regulati
16Complaint Problem Cause SolutionWater leaking from relief valve.A. Dirt lodged under seat of valve.1. Pressure has exceeded rating on relief valve a
17Complaint Problem Cause SolutionWater is running to drain continuously.A. Control valve is stuck in regeneration cycle.1. Electrical service to cont
Performance Data SheetCulligan® 10” and 12” Iron-Cleer® Water FiltersImportant Notice — Read this data sheet and compare the capabilities of the uni
19Records and DataImportant Data on Your Water FilterIt is advisable to have the salesperson or installer fill in the information below for your futur
Culligan Limited WarrantyCulligan® Iron-Cleer® Automatic Water FiltersYou have just purchased one of the finest water conditioners made. As an expres
21With Culligan You Get More Than A Quality ProductYou Get Your Water Expert, The Culligan Man®We’re here to provide you with fast, dependable service
Table of ContentsiiiSpecifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Introduction . .
This page intentionally left blank.iv
SpecificationsCulligan® Iron Cleer® Plus Filters10” Iron Cleer 12” Iron CleerControl Valve1” 5-cycle reinforced thermoplastic 1” 5-cycle reinforced th
IntroductionOperationStep 1.Aeration Operation Service CycleIn the service cycle, raw water enters the inlet port of the aeration tank and is directed
Shuttle Valve OperationIn the service position, water pressure holds the shuttle valve piston in the closed position, trapping the airhead in the aera
The concentration limits listed below reflect the maximum individual limit that each contaminant was tested for separately without any interference of
FamiliarizationPower LossThe AccuSoft® circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The capacitor is capable of maintaini